  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "A vulnerability affecting SALUS EV chargers allowed unauthorized access to diagnostic logs belonging to other chargers through shared FTP credentials embedded in firmware and insufficient access restrictions on the shared FTP logging service. Cross-customer log access was demonstrated during the reported research investigation. Server-side containment measures were applied in September 2026. The affected FTP service has since been permanently disabled, and a firmware update addressing the vulnerability has been released globally for the eight models listed in this advisory.",
        "title": "Advisory summary"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "For security questions or vulnerability reports, contact security@saluscontrols.com.",
      "issuing_authority": "SALUS Controls PLC issues this advisory for affected SALUS products and coordinates vulnerability handling with its technical partners.",
      "name": "SALUS Controls PLC",
      "namespace": "https://saluscontrols.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "Canonical CSAF version of SALUS security advisory ADVISORY-2026-0001.",
        "url": "https://saluscontrols.com/security/advisories/2026/advisory-2026-0001.json"
      }
    ],
    "title": "SALUS EV chargers — Cross-customer access to logs through shared FTP service",
    "tracking": {
      "current_release_date": "2026-11-13T13:00:00.000Z",
      "generator": {
        "date": "2026-11-12T12:00:34.306Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.6.19"
        }
      },
      "id": "ADVISORY-2026-0001",
      "initial_release_date": "2026-11-13T13:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-11-13T13:00:00.000Z",
          "number": "1",
          "summary": "Initial public release."
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "category": "product_name",
        "name": "EVT7UK",
        "product": {
          "name": "SALUS EVT7UK EV Charger",
          "product_id": "SALUS-EVT7UK",
          "product_identification_helper": {
            "model_numbers": [
              "EVT7UK"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EVT7EU",
        "product": {
          "name": "SALUS EVT7EU EV Charger",
          "product_id": "SALUS-EVT7EU",
          "product_identification_helper": {
            "model_numbers": [
              "EVT7EU"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EVT11EU",
        "product": {
          "name": "SALUS EVT11EU EV Charger",
          "product_id": "SALUS-EVT11EU",
          "product_identification_helper": {
            "model_numbers": [
              "EVT11EU"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EV7UK",
        "product": {
          "name": "SALUS EV7UK EV Charger",
          "product_id": "SALUS-EV7UK",
          "product_identification_helper": {
            "model_numbers": [
              "EV7UK"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EV7EU",
        "product": {
          "name": "SALUS EV7EU EV Charger",
          "product_id": "SALUS-EV7EU",
          "product_identification_helper": {
            "model_numbers": [
              "EV7EU"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EV11EU",
        "product": {
          "name": "SALUS EV11EU EV Charger",
          "product_id": "SALUS-EV11EU",
          "product_identification_helper": {
            "model_numbers": [
              "EV11EU"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EV7FR",
        "product": {
          "name": "SALUS EV7FR EV Charger",
          "product_id": "SALUS-EV7FR",
          "product_identification_helper": {
            "model_numbers": [
              "EV7FR"
            ]
          }
        }
      },
      {
        "category": "product_name",
        "name": "EV11FR",
        "product": {
          "name": "SALUS EV11FR EV Charger",
          "product_id": "SALUS-EV11FR",
          "product_identification_helper": {
            "model_numbers": [
              "EV11FR"
            ]
          }
        }
      }
    ]
  },
  "vulnerabilities": [
    {
      "acknowledgments": [
        {
          "names": [
            "Gareth Attrill"
          ],
          "summary": "SALUS Controls PLC thanks Gareth Attrill for reporting this vulnerability and cooperating during the investigation and remediation process."
        }
      ],
      "ids": [
        {
          "system_name": "SALUS Controls PLC",
          "text": "VULN-2026-0001"
        }
      ],
      "notes": [
        {
          "category": "description",
          "text": "Shared FTP credentials embedded in publicly available SALUS EV charger firmware, combined with insufficient access restrictions on the shared FTP logging service, enabled unauthorized access to diagnostic logs belonging to other chargers.",
          "title": "Vulnerability description"
        },
        {
          "category": "description",
          "text": "The affected product models are EVT7UK, EVT7EU, EVT11EU, EV7UK, EV7EU, EV11EU, EV7FR and EV11FR. Firmware v2.2.3 was confirmed affected on the reported EVT7UK. The complete affected firmware version ranges and the first fixed firmware version for each model remain subject to confirmation.",
          "title": "Affected firmware scope"
        },
        {
          "category": "other",
          "text": "Firmware v2.2.4 (0x8C) passed remediation testing on 26 October 2026. The engineering team has subsequently confirmed that the affected FTP service has been permanently disabled, and global release of a firmware update addressing the vulnerability has been confirmed for all eight listed models. Global release does not establish that the update has been installed on every device. Customers requiring assistance with checking their installed firmware or obtaining update instructions should contact security@saluscontrols.com and quote ADVISORY-2026-0001.",
          "title": "Firmware remediation status"
        },
        {
          "category": "other",
          "text": "The technical assessment dated 2 October 2026 records a CVSS v4.0 base score of 6.9 (Medium), with High remediation priority. Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N.",
          "title": "Technical severity"
        }
      ],
      "product_status": {
        "known_affected": [
          "SALUS-EVT7UK",
          "SALUS-EVT7EU",
          "SALUS-EVT11EU",
          "SALUS-EV7UK",
          "SALUS-EV7EU",
          "SALUS-EV11EU",
          "SALUS-EV7FR",
          "SALUS-EV11FR"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "date": "2026-09-29T07:00:00.000Z",
          "details": "Server-side restrictions were applied to the shared FTP account on 29 September 2026 at 07:00 UTC. Validation on 30 September confirmed that the tested directory-listing, download and deletion requests were denied. Authentication remained possible and a zero-byte test upload succeeded. These results establish containment of the tested access paths at that time, not complete FTP server shutdown. The initial containment required no customer installation or configuration change.",
          "product_ids": [
            "SALUS-EVT7UK",
            "SALUS-EVT7EU",
            "SALUS-EVT11EU",
            "SALUS-EV7UK",
            "SALUS-EV7EU",
            "SALUS-EV11EU",
            "SALUS-EV7FR",
            "SALUS-EV11FR"
          ]
        },
        {
          "category": "mitigation",
          "details": "The affected shared FTP logging service has been permanently disabled. This server-side measure required no customer installation or configuration change.",
          "product_ids": [
            "SALUS-EVT7UK",
            "SALUS-EVT7EU",
            "SALUS-EVT11EU",
            "SALUS-EV7UK",
            "SALUS-EV7EU",
            "SALUS-EV11EU",
            "SALUS-EV7FR",
            "SALUS-EV11FR"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "environmentalScore": 6.5,
            "environmentalSeverity": "MEDIUM",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 6.5,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "products": [
            "SALUS-EVT7UK",
            "SALUS-EVT7EU",
            "SALUS-EVT11EU",
            "SALUS-EV7UK",
            "SALUS-EV7EU",
            "SALUS-EV11EU",
            "SALUS-EV7FR",
            "SALUS-EV11FR"
          ]
        }
      ],
      "title": "Cross-customer diagnostic log access through shared FTP credentials"
    }
  ]
}